2011년부터 간판 및 LED 스트립 조명 공장

2011년부터 간판 및 LED 스트립 조명 공장

LED 라이트 시트 구매자 가이드: 모든 B2B 구매자가 확인해야 하는 7가지 기술 사양

Commercial lighting procurement is not a design decision. It is a risk decision. Illumination performance, compliance exposure, operating cost, and long-term maintenance all depend on measurable technical specifications. Marketing summaries are irrelevant at this level.

For B2B buyers, the LED light sheet is the primary validation document. It contains the photometric, electrical, and environmental metrics that determine whether a product will perform as specified once installed.

This guide explains the seven technical specifications that directly affect performance, lifecycle reliability, and project risk when sourcing a LED light sheet or related systems. Each metric can be verified in the technical documentation. Each has measurable commercial benchmarks.

7 Technical Specifications Every B2B Buyer Should Check

LED 라이트 시트

1. Luminous Efficacy (lm/W)

Luminous efficacy measures how efficiently electrical power is converted into visible light. It is expressed in lumens per watt (lm/W). This metric is often confused with brightness, but brightness is measured in lumens. Efficacy measures efficiency, not output.

In commercial-grade systems, realistic ranges for an LED light sheet are typically 110–160 lm/W at the system level, depending on driver quality and thermal management. Figures significantly above this range often reflect chip-level laboratory values rather than integrated system performance.

In real installations, efficacy directly affects operating cost and heat load. A sheet operating at 95 lm/W will consume substantially more energy to achieve the same lumen density as one operating at 140 lm/W. Over large retail or signage rollouts, that difference compounds into measurable cost increases.

If ignored, procurement teams risk approving products that meet brightness targets but fail energy modeling assumptions. To verify, check the “System Luminous Efficacy” or “Lumens per Watt” field in the LED light sheet, not just LED chip specifications.

2. Total Lumen Output (lm/m²)

LED 라이트 시트

Total lumen output per square meter determines usable brightness density. For sheet-based systems, lumen density is more relevant than total lumens per strip because installation area drives visual performance.

Interior architectural backlighting commonly requires 3,000–6,000 lm/m², depending on diffusion depth. Retail signage and lightbox applications may require 6,000–10,000+ lm/m², especially in high ambient environments. This is where a high brightness LED light sheet becomes necessary.

If lumen density is underspecified, the result is uneven illumination, shadowing behind graphics, or visible hot spots. Overcompensating with additional sheets increases power consumption and wiring complexity.

Verification appears in the LED light sheet under “Total Lumen Output,” “Luminous Flux per Area,” or photometric test results. Buyers should confirm testing distance and measurement conditions.

3. CRI & LED Binning Consistency

Color Rendering Index (CRI) measures how accurately a light source renders colors compared to natural light. For most commercial environments, CRI ≥80 is the baseline. Retail, fashion, and branded environments often require CRI ≥90.

Beyond CRI, binning consistency is critical. LED manufacturers classify diodes into bins based on chromaticity. If bin tolerance is not tightly controlled, multi-site rollouts can show visible color variation between installations.

In real-world deployment, inconsistent binning creates brand inconsistency across store networks. Walls installed months apart may not match visually. That is a procurement failure, not an installation issue.

The LED light sheet should specify CRI value and chromaticity tolerance, often expressed as SDCM (Standard Deviation of Color Matching). A commercial benchmark is ≤3 SDCM for uniform appearance.

4. Color Temperature (CCT) Accuracy

Correlated Color Temperature (CCT) defines the perceived warmth or coolness of white light. Commercial standards typically include:

  • 3000K for hospitality and warm retail environments
  • 4000K for offices and general commercial interiors
  • 6500K for high-visibility or technical spaces

Accuracy matters as much as nominal value. A 4000K system with ±500K tolerance may produce noticeable variation between batches.

In architectural installations, incorrect CCT shifts alter material perception and brand identity. In multi-phase projects, mismatched temperature ranges create visible segmentation between sections.

The LED light sheet should state nominal CCT and tolerance range. Look for ±100K to ±300K tolerance in commercial-grade products. Wider tolerances increase visual inconsistency risk.

5. Lumen Maintenance (L70 & TM-21)

LED 라이트 시트

L70 represents the number of operating hours until light output declines to 70 percent of its original value. It is not a failure point. It is a depreciation threshold.

Manufacturers often state “50,000 hours” without context. The more important validation is LM-80 test data combined with TM-21 projection methodology. TM-21 extrapolates long-term lumen maintenance based on measured performance.

For commercial projects, credible systems provide L70 ≥50,000 hours at specified ambient temperature, supported by TM-21 calculations. Without TM-21, lifespan claims are not technically substantiated.

If ignored, buyers risk premature lumen depreciation, leading to uneven brightness across installed areas. In the LED light sheet, verify LM-80 reference, TM-21 projection report, and test temperature conditions.

6. IP Rating & Environmental Protection

Ingress Protection (IP) rating indicates resistance to dust and moisture. The rating format follows IPXX, where the first digit relates to solids and the second to liquids.

IP20 is typical for indoor dry installations.
IP65 or higher is required for signage, exterior façades, or environments exposed to moisture.

In lightbox or façade applications, condensation can degrade circuitry and shorten operational life. Even interior retail signage near entrances may require elevated IP protection.

If the environmental rating is insufficient, corrosion and driver failure occur before projected lifecycle. The LED light sheet should clearly list IP rating, testing standard, and operating temperature range.

7. Voltage & Dimming Compatibility

Commercial LED sheet systems typically operate at 24V DC, which supports stable distribution across larger panels and reduces voltage drop compared to 12V systems.

Dimming compatibility must align with building control systems. Common commercial standards include 0-10V analog dimming 그리고 DALI digital control. Projects incorporating dimmable and rgbw LED light sheets require driver compatibility confirmation.

Incompatibility leads to flicker, uneven dimming curves, or integration failure with building automation systems. These issues often surface post-installation when remediation is costly.

The LED light sheet should specify operating voltage, maximum run length, driver type, dimming protocol compatibility, and PWM frequency where relevant.

LED 라이트 시트

조정 가능한 흰색 LED 시트

  • 크기(L x W ): 250mmx250mm/490mmx245mm
  • LED 유형: 2835 SMD
  • LED 수량: 200pcs/484pcs
  • 작동 전압: DC 24V
  • Power: 16W/40W
  • 색온도 조절 가능 범위: 2700K-6500K
  • 광속: 1600LM/3800LM
  • 크리: >90ra
  • 최소 절단 길이: 25mmx25mm/22.3mmx22.3mm
  • 디밍 가능: 예
  • 빔 각도: 120°
  • 방수 레벨: IP20 비방수, IP54 방수
  • 보증: 3년


Summary checklist for B2B Buyers

Technical Spec확인해야 할 사항Commercial Benchmark무시할 경우 위험
발광 효능System lm/W rating110–160 lm/WHigher energy cost, excess heat
Total Lumen Outputlm/m² under test conditions3,000–10,000+ lm/m² depending on useUneven brightness, shadowing
CRI & BinningCRI value, SDCM toleranceCRI ≥80 (≥90 retail), ≤3 SDCMColor inconsistency across sites
CCT AccuracyNominal CCT and tolerance±100K to ±300KVisual mismatch between batches
루멘 유지LM-80 & TM-21 dataL70 ≥50,000 hrs supported by TM-21Premature brightness loss
IP 등급IP classification & temp rangeIP20 indoor, IP65 signageMoisture damage, corrosion
Voltage & Dimming24V spec, control compatibility24V, 0-10V or DALIFlicker, integration failure

How to Read an LED sheet light spec

LED 라이트 시트

The LED light sheet is structured into photometric, electrical, thermal, and compliance sections. Luminous efficacy and total lumen output appear under photometric performance. CRI, CCT, and chromaticity tolerance are typically grouped within color characteristics. Voltage, current, and dimming compatibility are found in the electrical specifications table.

Lumen maintenance claims should reference LM-80 test reports and include TM-21 projections. If lifespan is stated without LM-80 data, the claim lacks technical foundation. Similarly, omission of bin classification or SDCM tolerance indicates potential color inconsistency risk.

Environmental protection appears under mechanical or compliance specifications. If IP rating is listed without reference standard, clarification is required before approval.

Incomplete documentation signals procurement exposure. A commercial supplier should provide a detailed data sheet, not a simplified marketing flyer.

Common Procurement Mistakes

One frequent error is approving products based solely on total lumen output without validating lumen density per area. Another is accepting lifetime claims without verifying TM-21 projection data. Multi-site buyers often overlook bin tolerance, resulting in visible color variation across branches. Voltage compatibility is sometimes assumed rather than confirmed, leading to driver replacement during commissioning.

Each of these failures originates from insufficient review of the LED light sheet.

결론

Commercial LED sheet procurement is a technical evaluation process. Performance, operating cost, and lifecycle reliability depend on measurable specifications, not marketing summaries.

Every approval decision should be supported by a verified LED light sheet. When the documentation confirms efficacy, lumen density, color stability, environmental protection, and electrical compatibility, project risk is significantly reduced.

Never rely on headline claims. Validate the data before deployment.

자주 묻는 질문

LED 모듈 맞춤형 솔루션_01LED 모듈 맞춤형 솔루션_01
사무실 및 상업용 조명 프로젝트를 위한 확장 가능한 맞춤형 LED 선형 모듈 솔루션
클라이언트는 동유럽에 기반을 둔 전문적인 선형 조명 디자이너 및 제조업체로 유럽 시장 전반에 걸쳐 광범위한 고객에게 서비스를 제공합니다. 그들의 핵심 사업은 사무실 및 상업용 응용 분야를 위한 맞춤형 선형 조명 솔루션에 중점을 두고 있으며, 조명 디자인, 조명기구 제조 및...
DALI 제어 LED 선형 조명이 현대적인 사무실 공간에 이상적인 이유
현대 사무실에서 조명은 조명을 넘어 사람들이 일하고 느끼는 방식을 형성합니다. LED 선형 조명은 깨끗한 디자인, 균일한 배광, 작업 공간 전반에 걸친 다용도성을 위한 표준이 되었습니다. DALI 제어 시스템과 페어링하면 스마트 디밍, 에너지 절약 및 중앙 집중식 조명 관리를 제공합니다. 이 글은 탐구...
현대식 사무실을 위한 LED 선형 조명현대식 사무실을 위한 LED 선형 조명
현대식 사무실을 위한 LED 선형 조명: 제품 선택에 대한 완벽한 가이드
현대적인 사무실 공간 디자인에서 LED 선형 조명은 주류 조명 솔루션이 되었습니다. 뛰어난 에너지 절약 성능과 미니멀한 미학 때문일 뿐만 아니라 직원의 집중도를 높이고 공간 레이어를 최적화하며 기업 이미지를 강화하는 데 대체할 수 없는 역할을 하기 때문입니다. 오픈플랜 사무실이든, 회의실이든...
LED 스트립 조명은 건강에 안전한가요?LED 스트립 조명은 건강에 안전한가요?
LED 스트립 조명은 사용하기에 안전한가요?
LED 스트립은 다용도성과 유연성으로 인해 가정 및 상업용 조명으로 점점 인기를 얻고 있습니다. 하지만 다른 전기 제품과 마찬가지로 사용하기에 안전한지, 인체에 해롭지는 않은지 의심스러울 수 있습니다. 이 글은 이러한 우려를 해소하고 필수 가이드라인을 제공하는 데 도움이 될 것입니다...
How-to-Choose-Between-3000K-4000K-5000K-and-6000KHow-to-Choose-Between-3000K-4000K-5000K-and-6000K
3000만원 대 4000만원 대 5000만원 대 6000만원: 차이점은 무엇인가요?
대부분의 사람들에게 색온도는 비교적 생소한 용어이지만 우리 생활의 모든 측면에 존재합니다. 조명처럼요. 사진. 색온도의 중요성은 광원의 정보를 제공하는 것뿐만 아니라 사람들의 감정에 영향을 미치는 것입니다. 행동과 삶의 질.색온도는 ...
LED 네온 플렉시블 조명의 장점LED 네온 플렉시블 조명의 장점
LED 네온 플렉시블 조명의 장점
오늘날 가장 일반적이고 적응력이 뛰어난 조명 대안 중 하나는 네온 조명입니다. 상업 공간을 밝히고 집 안의 아늑한 분위기를 조성하는 데 이상적인 선택입니다. 하지만 너무 다양한 종류와 색상으로 어디서부터 시작해야 할지 알기 어려울 수 있습니다.

공유하다:

페이스북
지저귀다
핀터레스트
링크드인
구독하다
알림
guest
0 댓글
가장 오래된
최신 가장 많이 투표된
인라인 피드백
모든 댓글 보기

SignliteLED 블로그 검색

카테고리

위로

지금 견적을 받으세요