标牌和 LED 灯带工厂,始于 2011 年

标牌和 LED 灯带工厂,始于 2011 年

抗 - 适合舒适的商业空间的眩光低UGR LED线性灯

Imagine walking into an office or a shopping mall and feeling instantly comfortable—thanks to Anti-Glare Low UGR LED Linear Lights—not squinting at harsh lights, not being distracted by glaring reflections.

In today’s commercial spaces, lighting is no longer just about brightness. With low UGR LED lighting (UGR ≤ 19), glare is minimized, and eyes are happier—whether you’re working on a report, browsing products, or attending a lecture. It’s about creating an environment where people can focus, shop, or study without visual fatigue.

These lights are carefully designed with smart optical components—like diffusers, lenses, and honeycomb louvers—to make sure light spreads evenly without harsh peaks. The result? A comfortable commercial lighting environment that enhances productivity, improves customer experience, and elevates the overall aesthetic of the space.

抗 - 眩光低UGR LED 线性灯

What Is UGR and Why It Matters in Lighting Design?

什么是UGR?

Unified Glare Rating (UGR) is a standardized metric developed by the CIE (International Commission on Illumination) to quantify visual discomfort caused by glare in indoor lighting environments. UGR provides a numerical value that indicates how likely a light source is to cause discomfort when viewed from a typical seated position.

UGR values range from 5 (very low glare) to 40 (extremely high glare). For commercial spaces such as offices, schools, and retail environments, maintaining a UGR below 19 is generally recommended to ensure a comfortable visual experience.

UGR Rating Reference

UGR ValueComfort LevelInstruction
10–19良好Glare is acceptable in most workspaces
20–22AcceptableGlare may be noticeable but not overly disturbing
22–25BorderlineGlare can be unpleasant
>25UnacceptableGlare is very unpleasant
YouTube 视频

How UGR Is Calculated?

UGR is not a fixed property of a luminaire but depends on the lighting installation as a whole. Factors that influence UGR include:

Luminance of light sources

  • Background luminance
  • Observer position & viewing angle
  • Room geometry
  • Surface reflectance
  • Luminaire arrangement (spacing, height, orientation)
How UGR Is Calculated

In practice, software such as Dialux, Relux, or AGi32 is commonly used to simulate these parameters and calculate UGR values. According to the TRILUX “UGR Table Method,” standardized room sizes, surface reflectance values, and observer positions are applied to make results comparable across different products.

Standardized arrangement of the observer and the horizontal luminaire plane, positioned at H = h – p – 1.2 (in meters) above the observer’s eye level for seated positions, where p represents the suspension length of the luminaire row.

Observer-and-Luminaire-Plane-Arrangement-for-UGR-Calculation

For narrow luminaire arrangements (s = 0.25 H), the UGR value remains almost independent of the observer’s viewing position.

UGR-Stability-with-Narrow-Luminaire-Spacing

With wider luminaire spacing, observer B1 experiences a lower UGR while observer B2 sees a higher UGR. However, both values generally stay below the UGR level observed in narrow luminaire arrangements.

UGR Variation with Wide Luminaire Spacing

请注意: According to EN 12464-1, UGR tables can also be based on luminaire distances greater than s = 0.25 H. For example, in Great Britain, s = 1.0 H is commonly used, which results in lower UGR values and higher luminaire efficiency. However, this requires designers to carefully check observer positions to avoid higher glare at certain viewing angles.

Why UGR Matters?

Enhancing Visual Comfort

Low UGR lighting reduces direct glare and hotspots, minimizing eye strain during prolonged activities such as working on a computer, reading, or attending classes.

Supporting Productivity

Well-controlled glare improves concentration and performance. Studies show that employees or students in low-glare environments maintain focus longer and experience less fatigue.

Creating a Professional and Inviting Atmosphere

In retail or hospitality settings, low-glare lighting ensures that products, displays, and architectural features are clearly visible without discomfort, improving customer experience.

Achieving UGR Targets

Manufacturers often label products as “UGR<19,” but this does not guarantee the light alone achieves the rating. Instead, it indicates that the luminaire’s optical design (e.g., diffusers, louvers, lenses) supports achieving the target when properly installed in a suitable environment.

Why UGR Matters
Standardized luminaire arrangements used in the UGR table method.
The observer’s viewing direction is shown across (left) and parallel (right) to the luminaire axis, which can be aligned with either the longer (top) or shorter (bottom) side of the room. Coordinates x (across) and y (parallel) indicate example positions, highlighted in blue and black for clarity.

Features of Anti-Glare Low UGR LED Linear Light

Low UGR LED linear lights are engineered to reduce visual discomfort and create comfortable commercial spaces. Their performance is determined not only by the LED chips but also by optical components, housing design, and precise light distribution.

Optical Components

Diffuser
目的: Evenly distributes light, reduces hotspots, and softens glare.                                                                       .
Types: Micro-structured PMMA/PC diffusers, frosted or matte surfaces.

Lens
目的: Controls beam angle, ensuring light is directed to the workspace, avoiding direct glare to the eyes.
Types: Linear lenses, optical-grade PC lenses.

Louver
目的: Shields direct light from line of sight, minimizing glare while maintaining brightness on working surfaces.
Material & Design: Aluminum or plastic; cell size, depth, and spacing directly affect UGR.

Reflector
目的: Optimizes light distribution, reduces high-luminance zones, and prevents direct glare.
材料: High-reflectivity aluminum or coated surfaces.

LED Chip and Housing

High CRI LED Chip
Ensures natural color rendering (CRI>80 or 90), reduces visual fatigue, and works synergistically with optical components to enhance comfort.

Housing Design
Deep-slot or shielded edge designs reduce direct brightness seen by occupants. Light trough depth and fixture geometry play a key role in lowering UGR.

Integration and Light Distribution

Combining the above components allows precise control of light direction and intensity, ensuring even illumination across work surfaces while keeping the UGR value low.

Designers can achieve UGR<19 in typical office, educational, or retail installations through careful selection of diffusers, lenses, and housing geometry.

Features-of-Anti-Glare-Low-UGR-LED-Linear-Light

Applications of Low UGR LED Linear Light

Low UGR LED linear lights are widely used in modern commercial and institutional spaces where visual comfort is a priority. By minimizing glare, they help create productive, welcoming, and aesthetically pleasing environments.

办公室照明

In open-plan offices, meeting rooms, and co-working spaces, glare-free lighting reduces eye strain and supports long hours of computer work. Maintaining UGR<19 is often a design requirement in corporate environments to comply with international lighting standards (e.g., EN12464).

Retail & Shopping Malls

Retail spaces benefit from low UGR lighting as it provides clear product visibility without causing discomfort to shoppers. Linear lights with anti-glare diffusers or louvers enhance merchandise display while keeping the shopping experience comfortable and inviting.

Educational Institutions

Classrooms, libraries, and lecture halls require lighting that supports concentration and reduces visual fatigue. Low UGR LED linear lights help students and teachers stay focused, creating an optimal environment for learning and reading.

Hospitality & Public Spaces

In hotels, lobbies, restaurants, and public waiting areas, lighting must balance comfort and aesthetics. Low UGR linear fixtures prevent discomfort for guests while enhancing architectural details, signage, and interior ambiance.

Comparison: Low UGR Linear Light vs. Conventional Lighting

When evaluating lighting for commercial spaces, it is important to compare low UGR LED linear lights with conventional fixtures such as standard fluorescent lamps, basic LED panels, or non-optimized linear lights. The differences highlight why glare control is essential in modern lighting design.

视觉舒适度

  • Low UGR Linear Light: Designed with diffusers, louvers, or reflectors to reduce glare, creating a soft and balanced illumination that minimizes eye strain.
  • Conventional Lighting: Often produces direct glare or visible bright spots, especially from bare tubes or low-quality panels, leading to discomfort during long exposure.

Compliance with Standards

  • Low UGR Linear Light: Meets requirements of EN12464, WELL Building Standard, and LEED lighting guidelines, especially the UGR<19 criterion in offices and classrooms.
  • Conventional Lighting: May fail to comply with modern glare requirements, making it unsuitable for projects where certification and visual comfort are important.

Productivity and User Experience

  • Low UGR Linear Light: Enhances focus, reduces fatigue, and creates a pleasant atmosphere, directly supporting higher productivity and customer satisfaction.
  • Conventional Lighting: Can cause eye discomfort, headaches, and reduced concentration, negatively affecting work efficiency and user experience.

Aesthetics and Architectural Integration

  • Low UGR Linear Light: Offers sleek designs, uniform light output, and minimal glare, enhancing the architectural aesthetics of modern offices, retail, and hospitality spaces.
  • Conventional Lighting: Outdated designs or uncontrolled light distribution may disrupt interior aesthetics and create uneven illumination.

Summary Table

方面 Low UGR Linear Light Conventional Lighting
眩光控制 UGR<19, ComfortableOften >22, Noticeable or harsh
StandardsMeets EN12464, WELL, LEEDMay fail requirements
视觉舒适度 Soft, balanced, eye-friendlyHarsh, causes strain
ProductivityImproves focus and well-beingReduces focus, may cause fatigue
美学 Modern, clean, architectural fitUneven light, outdated look
Low-UGR-Linear-Light
Input Voltage: AC100-277V / AC200-240V
Profile Size: W25*H85mm
Length Optional: 1200/ 1500/ 1800/ 2400 mm
Color Temperature (CCT): 3000K/ 4000K/ 6000K/ CCT
Lamp Luminous Efficiency (Lm/W): 100 Lm/W
Power: 40W/ 50W/ 60W/ 80W
Color Rendering Index (Ra): >80, >90
Light Source Type: LED SMD2835
Dimming Available: Non-dim/ 0-10V/ DALI Dimming
Main Material: Aluminum + PC / PMMA / Prismatic Diffuser
Shell Color: Black/ White/ Silver
Installation: Suspended/ Surface/ Wall Mounted

How to Select the Right Low UGR LED Linear Light & Buyer’s Checklist

When choosing anti-glare linear lighting for offices, schools, retail, or hospitality projects, it’s not enough to look at product datasheets. Buyers should verify whether the fixtures truly meet performance and compliance requirements. The following guidelines turn technical features into practical procurement checks.

Verify UGR Test Reports

  • Request official UGR test data from the supplier, not just marketing claims.
  • Confirm the values are tested under EN 12464-1 conditions (e.g., UGR ≤19 for offices/classrooms).

Request Samples for On-Site Evaluation

  • Check glare control, light uniformity, and comfort in a real project environment.
  • Place luminaires at intended mounting heights to simulate final effect.

Confirm Certification & Compliance

  • Look for CE, RoHS, UL, and EN 12464-1 compliance.
  • Certification ensures safety, quality, and suitability for international tenders.

Evaluate Project Flexibility

  • Does the manufacturer offer custom lengths, tunable CCT, or smart control (DALI/DMX)?
  • Flexibility ensures lighting can adapt to evolving project requirements.

Check Warranty & After-Sales Support

  • A minimum of 3–5 years warranty is recommended.
  • Reliable after-sales service reduces risks in long-term projects.

Buyer’s Checklist

标准What to Verify
UGR RatingRequest tested report, offices/classrooms ≤19, industry ≤16
Sample EvaluationCheck glare control, uniformity, comfort in real space
认证EN 12464-1, CE, RoHS, UL, or local approvals
灵活性Custom lengths, tunable CCT, DALI/DMX options
Warranty & Service3–5 year warranty, reliable after-sales support

结论

Low UGR LED linear lights represent a significant advancement in commercial and institutional lighting, offering a balanced combination of visual comfort, energy efficiency, and design flexibility. By understanding the concept of UGR and selecting fixtures with well-engineered optical components, buyers can create environments that reduce glare, enhance productivity, and provide an enjoyable experience for occupants. From offices and classrooms to retail spaces and hospitality environments, low UGR lighting is increasingly recognized as a standard for modern, human-centric illumination.

中国十大LED植物生长灯制造商(2025年更新名单)中国十大LED植物生长灯制造商(2025年更新名单)
中国十大LED植物生长灯制造商(2025年更新名单)
随着全球对可持续农业、垂直农业和受控环境可接受种植 (CEA) 的需求日益增长,LED 植物生长灯已成为提高作物产量、降低能耗和实现全年种植的关键技术。无论是北美的商业大麻种植、欧洲的水培蔬菜种植,还是垂直……
用于商业温室和室内农场的高功率全光谱 LED 种植灯
在现代室内农业和温室栽培中,照明不仅仅是一种补充,它还是植物健康、产量和质量的关键因素。高功率全光谱 LED 种植灯已成为专业种植者的首选解决方案,旨在最大限度地提高效率和作物产量。但是,面对市场上数不胜数的型号,...
DMX512LED灯条芯片的用户指南DMX512LED灯条芯片的用户指南
DMX512LED灯条芯片的用户指南
DMX512芯片为核心模块控制的宏LED灯条,通过解码的DMX512协议的命令,精确调节的LED灯亮,色彩,并且动态效应。 在建筑照明、娱乐场所的照明,和其他方案,芯片的议定书》的兼容性和扩展能力显着提高一级的系统...
购买 LED 灯条的完整指南购买 LED 灯条的完整指南
购买 LED 灯条的完整指南
LED 灯条是一种日益流行的照明形式,是商业和住宅照明应用中经济实惠的选择。购买 LED 灯条看似相对简单,但要确保买到正确类型的 LED 灯条,您需要考虑很多问题...
板条墙的适用场景板条墙的适用场景
板条墙和木板应用中的 LED 灯条
LED 灯条是板条墙的绝佳补充,可提供功能性和装饰性照明。它们可以突出展示物品,烘托氛围,并提高较暗区域的能见度。有几种 LED 灯条与板条墙兼容: 1.LED 灯条:LED 灯条高效节能、使用寿命长...
如何安装 LED 灯条如何安装 LED 灯条
如何安装 LED 灯条?
随着天花板的样式越来越多,我们家中安装的灯具种类也越来越多。例如,老房子里的灯基本上都是吊灯或吸顶灯。但是,如果你现在看看,就会发现灯带、射灯和筒灯...

分享:

Facebook
叽叽喳喳
Pinterest
LinkedIn
订阅评论
提醒
来宾
0 评论
最老的
最新 最多投票
内联反馈
查看所有评论

搜索 SignliteLED 博客

类别

返回顶部

立即获取报价