Usine de signalisation et d'éclairage à bandes LED depuis 2011

Usine de signalisation et d'éclairage à bandes LED depuis 2011

CEI 62471 bleu danger expliqué

Blue light is a natural part of the visible spectrum, but modern LED lighting contains a proportionally higher amount of blue wavelengths—typically in the 400–500 nm range—due to the way white LEDs are manufactured. Most white LEDs use a blue LED chip paired with phosphor coating to generate full-spectrum white light. While this technology provides high efficiency and excellent lumen output, it also introduces concerns about blue light hazard, a photochemical risk to the human retina caused by excessive exposure to high-energy blue radiation.

In recent years, regulators, lighting designers, and OEM manufacturers have paid increasing attention to the potential effects of blue light. Long-term or high-intensity exposure may contribute to retinal stress, visual discomfort, and circadian rhythm disruption. As LED lighting becomes widely used in offices, homes, schools, commercial spaces, and displays, understanding and controlling blue light hazard has become essential for ensuring both visual safety and compliance with photobiological standards.

This article focuses on blue light hazard as defined in IEC 62471, explaining the key technical metrics, risk group classifications, and how to choose LED strip lights with lower blue light hazard for professional lighting applications.

What Is Blue Light Hazard Under IEC 62471?

Blue light hazard refers to the potential photochemical damage to the retina caused by exposure to high-energy blue wavelengths, typically within 400–500 nm. When the eye is exposed to intense blue light for a sufficient duration, reactive oxygen species can form in retinal tissues, accelerating retinal cell degradation. This effect is cumulative and depends on both the intensity and exposure time, making it a critical safety consideration for lighting products viewed directly, such as LED strips, modules, and displays.

IEC 62471 is the internationally recognized standard that evaluates the photobiological safety of lamps and lamp systems. It defines measurement methods, hazard action spectra, exposure limits, and risk group classifications for different photobiological risks—including blue light hazard, UV hazard, and IR radiation hazard. For blue light evaluation specifically, IEC 62471 uses blue-light-weighted radiance and calculates maximum safe exposure times to determine the appropriate risk group.

As LED lighting technology continues to advance, compliance with IEC 62471 becomes essential. Because LEDs often have strong blue peaks due to their phosphor-converted design, they must undergo blue light hazard testing to ensure they meet safety thresholds for human exposure. Whether for residential, commercial, or professional applications, LED products are expected to be classified as RG0 or RG1 to enter many global markets, making IEC 62471 testing a mandatory part of LED product development.

blue light hazard to eyes

Key Technical Parameters for Evaluating Blue Light Hazard

1. Blue Light Weighted Radiance (L_B)

Blue Light Weighted Radiance (L_B) is the core parameter used in IEC 62471 to quantify blue light hazard. It represents the radiance of a light source weighted by the blue light hazard function B(λ), which emphasizes wavelengths most harmful to the retina (around 435–440 nm). The unit is W·m⁻²·sr⁻¹, expressing how much blue-weighted energy reaches the eye per unit area and per unit solid angle.

How It Is Determined:

Testing involves measuring the spectral radiance of the source using a calibrated spectroradiometer. Each wavelength component is multiplied by the blue hazard weighting function B(λ), and the integration across 300–700 nm yields the final L_B value. IEC 62471 requires measurements at a standardized distance—typically 200 mm—and mandates that the test captures the maximum luminance point of the source. For LED strips, this means measuring the brightest chip or hotspot. COB strips usually show smoother radiance distribution, resulting in lower L_B compared with point-source SMD strips.

Blue Light Weighted Radiance test

2. Blue Light Radiant Exposure (H_B)

Blue light radiant exposure (H_B) refers to the total amount of blue-light-weighted energy delivered to the retina over time, taking both radiance and exposure duration into account. While L_B describes intensity at a moment, H_B represents cumulative exposure and is expressed in J·m⁻²·sr⁻¹. IEC 62471 uses H_B as a supporting parameter in scenarios where the source is extended or viewed at close range for longer periods. This parameter becomes essential in applications such as task lighting, displays, and luminaires installed in near-field environments.

3. Blue Light Hazard Exposure Limit (t_max)

To determine how long a person can safely view a light source, IEC 62471 defines the maximum permissible exposure time (t_max). It is derived by comparing the measured L_B to the exposure limit defined for blue light hazard. The simplified IEC expression is:

t_max = 100 / L_B

(Valid when L_B ≥ 100 W·m⁻²·sr⁻¹)

This means that as blue-light-weighted radiance increases, the allowable safe viewing time decreases sharply. For example, if L_B is 200 W·m⁻²·sr⁻¹, the maximum safe exposure would be just 0.5 seconds. This formula guides risk group classification and helps determine whether a product falls into RG0 (no risk), RG1 (low risk), RG2 (moderate risk), or RG3 (high risk). In LED lighting—especially strips and modules designed for direct viewing—meeting the t_max threshold is critical for ensuring safe usage and regulatory compliance.

YouTube vidéo

IEC 62471 Blue Light Hazard Risk Group Classification

IEC 62471 classifies lighting products into four risk groups based on their blue-light-weighted radiance (L_B) and the corresponding maximum safe exposure time (t_max). These categories help determine whether a product is safe for direct human viewing.

1. Risk Group 0 (RG0 – Exempt)

No photobiological risk.

Limit: L_B ≤ 100 W·m⁻²·sr⁻¹ or t_max ≥ 100 s.

2. Risk Group 1 (RG1 – Low Risk)

No hazard under normal viewing conditions.

Limit: L_B ≤ 10,000 W·m⁻²·sr⁻¹ or t_max ≥ 0.01 s.

3. Risk Group 2 (RG2 – Moderate Risk)

Hazard only if the viewer intentionally stares at the source.

Limit: L_B ≤ 400,000 W·m⁻²·sr⁻¹.

4. Risk Group 3 (RG3 – High Risk)

Hazard from even momentary exposure.

Limit: L_B > 400,000 W·m⁻²·sr⁻¹.

Example Blue Light Hazard Levels for Different Lighting Products

Lighting Product TypeTypical CCTOptic / DiffusionTypical Risk Group
COB LED Strip (frosted cover)3000KStrong diffusionRG0
COB LED Strip (bare)4000KNo coverRG1
SMD 2835 LED Strip (high density)4000KNo coverRG1
SMD 5050 RGB StripMixed wavelengthsNo coverRG1
Linear Light with PC Diffuser3 000 à 4 000 000Frosted diffuserRG0
LED Downlight3 000 à 5 000 000Lens + reflectorRG1
High-Bay Industrial Light5000–6000KNarrow beamRG2
Stage / Studio LED Spotlight6000–8000KConcentrated beamRG2–RG3

How to Choose LED Strip Lights with Lower Blue Light Hazard

1. Choose Lower CCT LED Strips

Warm white LED strips (2700K–4000K) contain significantly less high-energy blue wavelength content. Lower CCT options naturally reduce blue light hazard and are ideal for residential, hospitality, and commercial ambient lighting.

2. Select High-CRI LED Strips

High-CRI LEDs use improved phosphor formulations that produce a smoother, fuller spectrum with reduced blue peaks. CRI 90+ or CRI 95+ strips generally deliver safer optical performance compared with low-CRI LEDs.

3. Prefer COB LED Strips Over SMD

COB strips feature continuous phosphor-coated emitters that eliminate intense point-source hotspots. Their uniform luminance results in lower blue-light-weighted radiance (L_B), making COB a safer choice than SMD in close-viewing applications.

Bande LED COB de couleur mono pour éclairage de miroir

Seamless COB Strip Light, Ra90, Compiant with IEC 62471

Numéro de modèle : FYX08T480X
Tension d'entrée : DC12V/24V
Puissance : 11W/m
QTÉ DE LED : 480 LED/m
CCT : 2700K, 3000K, 4000K, 6500K
CRI: >95
Efficacité : 105 lm/W
Angle du faisceau : 180°.
Section de coupe : 25mm/50mm
Indice de protection IP : IP20/IP65/IP67/IP68
Garantie : 3 ans

4. Choose High-Efficacy, Low-Power Strips

LEDs driven at lower current generate less radiance and produce a more stable spectrum. High-efficiency low-wattage designs reduce both blue peak intensity and thermal stress. Check SignliteLED 180lm/W strip light FQM10T128C.

5. Use Diffused Solutions

Strips paired with diffusers—such as frosted silicone tubes, neon flex, or rigid aluminum channels with PC covers—significantly reduce peak luminance, lowering blue light hazard while improving visual comfort.

Top Bend T1010 Bande Néon LED en Silicone

Top Bending Neon Strip Light

Model No.: NQX1010TC
Tension d'entrée : DC12V/24V
Watts : 8W/m
Qté de LED : SMD2835 120LEDs/m
Température de couleur : 2700K/4000K/6500K
CRI: Ra>80
Min Bending Diameter: 25mm
Longueur de la table de coupe : 100 mm
Longueur : 5 mètres/rouleau

6. Choose LED Strips with IEC 62471 Certification

Always request a complete IEC 62471 report. Products rated RG0 or RG1 ensure compliance with global photobiological safety requirements.

SignliteLED offers IEC 62471-certified COB strip lights, low-CCT SMD LED strips, neon flex, and LED modules, providing safe and reliable solutions for professional lighting projects.

RG0 LED strip light

Schéma de l'interface USB DMX de SLESA-U9 entre l'ordinateur et les appareils LED DMX512Schéma de l'interface USB DMX de SLESA-U9 entre l'ordinateur et les appareils LED DMX512
NA Interface intelligente DMX512 : la meilleure interface DMX pour les petites salles
Dans les systèmes de contrôle de l'éclairage, le choix de la meilleure interface DMX 512 peut faire la différence entre une configuration d'éclairage simple et fiable et un mal de tête constant. L'interface intelligente NA (interface SLESA-U9 USB DMX512) est conçue comme une interface DMX professionnelle et abordable pour les petites salles, l'éclairage de scène, l'éclairage architectural, les bandes LED et les fontaines. ça...
Le guide ultime des slips de LED étanchesLe guide ultime des slips de LED étanches
Le guide ultime des slips de LED étanches
Dans l'éclairage architectural, l'éclairage commercial et les projets d'éclairage résidentiel, la fiabilité et la durabilité sont souvent aussi importantes que la luminosité et l'esthétique. L'une des causes les plus courantes de défaillance des bandes LED dans les applications réelles est une imperméabilisation, une imperméabilisation ou une imperméabilisation inadéquats. Une bande qui semble parfaite dans une salle d'exposition peut...
Lumières de profil circulaire pour intérieurs commerciauxLumières de profil circulaire pour intérieurs commerciaux
Éclairage de profilé LED – Formes linéaires, courbes et personnalisées
Introduction – L'éclairage n'est plus un éclairage linéaire. La conception de l'éclairage va aujourd'hui bien au-delà des lignes droites. Dans l'architecture moderne et les intérieurs commerciaux, l'éclairage joue un rôle essentiel dans la définition de l'identité visuelle d'un espace, non seulement dans sa fonction, mais dans sa forme. Notre système d'éclairage à profil LED modulaire prend en charge une large gamme de configurations, y compris...
Ultimate-Guide-on-Aluminum-Profile-for-LED-Strip-Lighting (en anglais)Ultimate-Guide-on-Aluminum-Profile-for-LED-Strip-Lighting (en anglais)
Guide ultime sur les profilés en aluminium pour les bandes LED
Les canaux LED en aluminium, également appelés profilés LED ou boîtiers, sont des extrusions spécialement conçues pour donner à vos installations de bandes LED un aspect élégant et poli. Ces canaux permettent de créer facilement des installations personnalisées adaptées à votre style préféré de canal LED et de bande LED. Nous...
Quels sont les avantages des lampes LED au néon ?Quels sont les avantages des lampes LED au néon ?
Quels sont les avantages des néons LED ?
Les néons LED ont récemment gagné en popularité pour l'éclairage commercial et résidentiel. Les néons LED offrent des solutions d'éclairage vibrantes et vives avec une consommation d'énergie et un effet environnemental moindres que les néons traditionnels. Nous discuterons des avantages des néons LED et des raisons pour lesquelles ils constituent un investissement judicieux pour...
Qu'est-ce qu'une bande LED COB ?Qu'est-ce qu'une bande LED COB ?
Une bande LED COB : qu'est-ce que c'est ?
De l'éclairage d'appoint à l'éclairage d'ambiance, les bandes LED deviennent de plus en plus courantes dans de nombreux contextes. La bande LED à puce sur carte (COB) est un type de bande LED relativement nouveau par rapport à la technologie LED SMD (Surface-Mounted Device) conventionnelle. Elle présente des avantages particuliers. Nous allons nous pencher sur les détails...

Partager:

Facebook
Gazouillement
Pinterest
LinkedIn
S’abonner
Notification pour
invité
0 Commentaires
Le plus ancien
Le plus récent Le plus populaire
Commentaires en ligne
Afficher tous les commentaires

Rechercher dans le blog SignliteLED

Catégories

Vers le haut

Obtenez un devis maintenant