Fabbrica di segnaletica e illuminazione a strisce LED dal 2011

Fabbrica di segnaletica e illuminazione a strisce LED dal 2011

Rapporto di test completo sulla caduta di tensione della striscia LED

LED strips are widely used for decoration and lighting, but voltage drop issues often cause significant brightness reduction at the ends. This report, based on product test data developed by the engineering department, aims to evaluate voltage drop characteristics and provide guidance for production and installation.

Obiettivo del test

This test report, completed by the Engineering Department, conducts systematic testing on voltage drop for LED strips (including SMD and COB strips). The objective is to verify the magnitude of voltage drop in standard strips and, based on the test data, evaluate whether the strip design is reasonable and meets user requirements, thereby enabling further improvements.

Measurement Equipment and Environment

  • Digital Multimeter (FLUKE), 12V/24VDC Regulated Power Supply, Constant-Temperature Soldering Iron
  • Temperature: 28°C ±5°C
  • Humidity: 65% ±5%

Test Sample

A total of 12 pieces, including 6 pieces of Strisce LED SMD and 6 pieces of Strisce LED COB.

Striscia LED SMD
ArticoloNumber of LEDsTensioneLength of the LED StripPCB Larghezza
160 LEDs/m12V10m8 mm
2120 LEDs/m12V10m8 mm
3120 LEDs/m24V10m8 mm
4120 LEDs/m24V5M5 mm
5120 LEDs/m24V Constant Current5M10 mm
6240 LEDs/m24V10m10 mm
Striscia LED COB
ArticoloNumber of LEDsTensioneLength of the LED StripPCB Larghezza
1320 LEDs/m12V5M8 mm
2320 LEDs/m24V5M8 mm
3384 LEDs/m24V5M8 mm
4480 LEDs/m12V10m8 mm
5528 LEDs/m12V5M10 mm
6528 LEDs/m24V10m10 mm

Testing Method

1) Adjust the DC power supply to output the correct voltage according to the LED strip’s voltage specifications. Verify the voltage accuracy using a multimeter.

2) Test the voltage value at the end point of each meter of LED strip using a multimeter and record the data.

3) Test the current data for each meter of LED strip using a multimeter. Calculate the power per meter using the formula P=UI and record the data.

4) After completing voltage and current measurements for each meter, solder the next meter of LED strip using a soldering iron. Repeat steps 2 and 3 until testing reaches the end point.

5) Record and preserve all data.

SMD LED Strip Voltage Drop Test Data

Tensione scendere saggiare Report per 60LED/m 12V LED Striscia
Lunghezza1M2M3M4 milioni5M6m7m8m9m10mPotenza(W)PCB scherzo
10m10.349.559.028.658.408.238.118.048.007.9815.24Width 8mm
copper
thickness:
18/25μm
9m10.559.699.128.738.478.298.188.128.10 15.12
8m10.569.709.138.768.518.358.268.24  15.00
7m10.559.719.168.808.588.468.41   14.88
6m10.549.739.218.898.728.67    14.40
5M10.579.809.339.088.89     14.16
4 milioni10.679.979.609.48      13.56
3M10.8110.2810.10       12.36
2M11.1410.84        9.79
1M11.64         5.77
Nota: The middle value represents voltage, with units in volts (V).
Table 1

Voltage Drop Test Report for 120LEDs/m 12V LED Strip
Lunghezza1M2M3M4 milioni5M6m7m8m9m10mPotenza(W)PCB Spec
10m10.499.669.118.748.488.308.188.108.068.0424.00Width 8mm,
copper
thickness:
35/35μm
9m10.499.669.128.758.498.338.228.168.17 23.82
8m10.509.679.138.778.538.388.308.27  23.72
7m10.509.689.168.828.608.488.45   23.54
6m10.519.729.228.918.748.69    23.19
5M10.549.789.339.089.01     22.72
4 milioni10.629.939.579.46      21.86
3M10.7710.2310.07       20.04
2M11.0510.82        16.20
1M11.61         9.80
Nota: The middle value represents voltage, with units in volts (V).
Table 2

Voltage Drop Test Report for 120LEDs/m 24V LED Strip
Lunghezza1M2M3M4 milioni5M6m7m8m9m10mPotenza(W)PCB Spec
10m22.5621.5020.6720.0119.4919.1018.8018.6018.4918.4641.95Width 8mm,
copper
thickness:
35/35μm
9m22.5821.5620.7620.1419.6719.3119.0818.9418.89 41.00
8m22.6321.6420.8820.3119.8919.6119.4319.38  40.15
7m22.7021.7521.0620.5620.2120.0119.94   38.40
6m22.8021.9321.3220.9120.6720.59    36.38
5M22.9122.1421.6621.3721.28     33.36
4 milioni23.0622.4822.1322.02      29.47
3M23.2822.8922.77       24.00
2M23.5623.42        17.00
1M23.91         9.00
Nota: The middle value represents voltage, with units in volts (V).
Table 3

Tensione scendere saggiare Report per 120LED/m 24V LED Striscia
Lunghezza1M2M3M4 milioni5M     Potenza(W)PCB scherzo
5M23.3322.9222.6322.4722.42     21Width 5mm,
copper
thickness:
35/35μm
4 milioni23.5223.2123.0322.97      17.70
3M23.6523.3923.34       13.90
2M23.7223.63        9.30
1M23.95         4.80
Nota: The middle value represents voltage, with units in volts (V).
Table 4

Tensione scendere saggiare Report per 120LED/m 24V costante Attuale LED Striscia
Lunghezza1M2M3M4 milioni5M     Potenza(W)PCB scherzo
5M22.6521.9321.4221.1221.02     80.64Width 10mm
copper
thickness:
25/25μm
4 milioni22.9222.4122.1122.00      63.12
3M23.2522.9422.83       47.52
2M23.5523.45        31.68
1M23.84         16.08
Nota: The middle value represents voltage, with units in volts (V).
Table 5

Tensione scendere saggiare Report per 240LED/m 24V LED Striscia
Lunghezza1M2M3M4 milioni5M6m7m8m9m10mPotenza(W)PCB scherzo
10m22.7621.1821.1720.6020.1419.7919.5219.3419.2319.2089.52Larghezza 10 mm
copper
thickness:
25/25μm
9m22.8021.9521.2720.7420.3220.0019.8019.6819.64 86.80
8m22.8822.0821.4520.9720.6220.3720.2220.18  83.52
7m22.9622.2221.6521.2420.9520.7820.73   78.91
6m23.0522.4021.9221.5921.4021.34    72.96
5M23.1822.6222.2422.5821.96     65.40
4 milioni23.3322.9122.6622.58      55.92
3M23.5123.2323.15       44.44
2M23.7323.64        31.20
1M23.97         16.00
Nota: The middle value represents voltage, with units in volts (V).
Table 6

Test Results Statistics Table

ArticoloLEDs/mLength(m)Starting Voltage(V)Endpoint Voltage(V)Tensione Drop
16010127.9833.5%
212010128.0433.0%
3120102418.4623.1%
412052422.426.6%
512052421.0212.4%
6240102419.220%

Summary Analysis

For the 60 LEDs/m and 120 LEDs/m light strips in Tables 1 and 2, the voltage drops to 7.98V and 8.04V, respectively, at a 10-meter length. The maximum voltage drop reaches 33.5%, indicating a significantly excessive voltage drop. Since both 60-LED and 120-LED strips consist of three LEDs in series (3V x 3 = 9V), ideally, the voltage drop should be maintained above 9V. Therefore, the voltage drop values for these two LED strips need improvement. This can be achieved by widening the circuit board or thickening the copper foil, or by controlling the LED forward voltage (VF) within a range below 2.8V.

Tables 3, 4, 5, and 6 all use a DC 24V power supply with 6 LEDs in series. We calculate the voltage required for the LEDs in series: 3V x 6 = 18V. Among all endpoint test values, Table 3 shows the lowest voltage drop at 18.46 V, exceeding the 18 V requirement and essentially meeting the voltage for 6 LEDs in series, thus qualifying as acceptable. Figure 5 employs constant-current mode, maintaining consistent power output of 16 W/m at both ends with negligible brightness decay, demonstrating excellent consistency.

Causes of High Voltage Drop:

This primarily results from excessive strip length and current, increasing PCB resistance and “consuming” voltage. Excessive voltage drop directly causes noticeable dimming at the strip’s end and may even lead to color distortion.

PANNOCCHIA LED Strip Voltage Drop Test Data

Tensione scendere saggiare Report per 320LEDs/m 12V PANNOCCHIA LED Striscia
Lunghezza1M2M3M4 milioni5M     Potenza(W)PCB scherzo
5M11.4011.0710.8710.7710.73     25.20Width 8mm
copper
thickness:
25/25μm
4 milioni11.4011.1010.9510.90      24.00
3M11.4511.2111.14       22.80
2M11.5611.45        19.20
1M11.81         12.00
Nota: The middle value represents voltage, with units in volts (V).
Table 1

Tensione scendere saggiare Report per 320LEDs/m 24V PANNOCCHIA LED Striscia
Lunghezza1M2M3M4 milioni5M     Potenza(W)PCB scherzo
5M23.5823.2623.0322.9022.86     33.60Width 8mm
copper
thickness:
25/25μm
4 milioni23.6523.3823.2323.00      29.76
3M23.7523.5723.5123.18      24.40
2M23.8823.82        17.20
1M24.00        9.00
Nota: The middle value represents voltage, with units in volts (V).
Table 2

Tensione scendere saggiare Report per 384LEDs/m 24V PANNOCCHIA LED Striscia
Lunghezza1M2M3M4 milioni5M     Potenza(W)PCB scherzo
5M23.6723.4123.2323.1223.08     46.30Width 8mm,
copper
thickness:
25/50μm
4 milioni23.7623.5623.4523.42      38.10
3M23.8523.7423.70       29.20
2M23.9523.91        19.80
1M24.00         10.10
Nota: The middle value represents voltage, with units in volts (V).
Table 3

Tensione scendere saggiare Report per 480LED/m 12V PANNOCCHIA LED Striscia
Lunghezza1M2M3M4 milioni5M6m7m8m9m10mPotenza(W)PCB scherzo
10m11.3310.9710.7310.5710.4610.3810.3310.2910.2710.2624.70Width 8mm
copper
thickness:
25/25μm
9m11.3310.9810.7410.5810.4710.4010.3510.3210.31 24.60
8m11.3310.9810.7510.5910.4910.4310.3910.38  24.40
7m11.3310.9810.7610.6210.5210.4710.45   24.20
6m11.3411.0010.7810.6610.5810.56    24.00
5M11.3511.0211.8310.7310.70     23.50
4 milioni11.3811.0810.9310.88      22.60
3M11.4411.2011.13       21.00
2M11.5611.45        17.40
1M11.80         10.60
Nota: The middle value represents voltage, with units in volts (V).
Table 4

Tensione scendere saggiare Report per 528LEDs/m 12V PANNOCCHIA LED Striscia
Lunghezza1M2M3M4 milioni5M     Potenza(W)PCB scherzo
5M11.4311.1110.90 10.7910.76     34.44Width 10mm
copper
thickness:
25/25μm
4 milioni11.4511.1711.01 10.96      32.88
3M11.5211.3111.23       29.52
2M11.6311.53        23.40
1M11.89         14.40
Nota: The middle value represents voltage, with units in volts (V).
Table 5

Tensione scendere saggiare Report per 528LEDs/m 24V PANNOCCHIA LED Striscia
Lunghezza1M2M3M4 milioni5M6m7m8m9m10mPotenza(W)PCB scherzo
10m23.3722.9322.5722.2922.0721.8921.7721.6921.6421.6270.80Width 10mm
copper
thickness:
25/25μm
9m23.3822.9522.6122.3422.6021.9721.8722.0421.80 69.36
8m23.4022.9822.6622.4122.2322.1122.0322.01  67.20
7m23.4223.0322.7322.5222.3622.2822.24   64.80
6m23.4823.1322.8522.6722.5722.53    61.20
5M23.5223.2223.0022.8822.83     55.92
4 milioni23.6123.3623.2123.16      48.96
3M23.7023.5323.47       39.84
2M23.8223.76        28.32
1M23.94         15.20
Nota: The middle value represents voltage, with units in volts (V).
Table 6

Test Results Statistics Table

ArticoloLEDs/mLength(m)Starting Voltage(V)Endpoint Voltage(V)Tensione Drop
132051210.7310.6%
232052422.864.7%
338452423.083.8%
4480101210.264.5%
552851210.7610.3%
6528102421.629.9%

Conclusione

Under 12V power supply, the voltage drops in Figures 1 and 5 are both around 10%, indicating slightly higher values. Figure 4 exhibits an excellent performance with a lower voltage drop of 4.5%.

Under 24V power supply, Figures 2 and 3 exhibit voltage drops of 4.7% and 3.8%, respectively, demonstrating excellent performance. Figure 6 shows a drop of 9.9%, which is slightly higher. Figure 3 achieves the lowest drop due to its PCB substrate copper foil thickness of 50 μm—twice as thick as the 25 μm thickness of others—which is the primary reason for its minimal voltage drop.

Among the COB LED strip voltage drop test results, the largest drop was 10.6% in Figure 1, while the smallest was 3.8% in Figure 3. Their voltage drop ranges fall within acceptable limits, and all six COB LED strips meet product testing requirements.

Appendix: LED Industry Voltage Drop Standards

Industry standards for LED strip voltage drop typically reference international specifications like IEC 62717, with core requirements including:

  • Voltage Stability: Current variation ≤ ±5% when rated voltage fluctuates by ±10%
  • Voltage Drop Limit: No specific percentage specified, but supply voltage must remain stable within ±0.2%
  • ‌Test Conditions: Conducted at 25°C ±1°C with relative humidity ≤65%

In practical applications, voltage drop for 12V systems is recommended to be controlled within 10%, while 24V systems should maintain it below 5%. Testing requires a constant current source to ensure LEDs operate at specified current values.

SPD vs Surge Arrester: qual è la differenza?
Nel mondo di oggi, gli impianti elettrici stanno diventando sempre più sofisticati e sensibili. Anche un piccolo sbalzo di corrente può causare gravi danni, con conseguente costoso fermo e guasti alle apparecchiature. Ecco perché la protezione contro le sovratensioni è essenziale per qualsiasi installazione moderna. Tuttavia, molti ingegneri e acquirenti spesso confondono gli SPD (dispositivi di protezione contro le sovratensioni) con sovratensione...
Quando-to-scelta-12V-24V-48V-LED-Lights-GuideQuando-to-scelta-12V-24V-48V-LED-Lights-Guide
Quando scegliere i sistemi a strisce LED a 12V, 24V o 48V? (Aggiornato per uso commerciale)
Introduzione Installazioni di illuminazione a strisce a LED, la selezione della tensione è spesso sottovalutata, ma influisce direttamente sulla consistenza della luminosità, sull'efficienza energetica e sui costi di manutenzione a lungo termine. Molti installatori hanno sperimentato situazioni frustranti: strisce LED che si attenuano a metà corsa o frequenti alimentazioni necessarie dopo l'installazione. Nella maggior parte dei casi, questi problemi sono causati dalla scelta...
I 10 principali produttori di strisce al neon LED in Cina (2025)
I 10 principali produttori di strisce al neon a LED in Cina svolgono un ruolo fondamentale nel soddisfare la crescente domanda globale di soluzioni di illuminazione flessibili, efficienti dal punto di vista energetico e di grande impatto visivo. Queste strisce al neon a LED sono diventate la scelta preferita per le applicazioni architettoniche, commerciali e di segnaletica. Grazie alla loro capacità di creare progetti personalizzati...
Perché l'illuminazione è essenziale per le conversioni di furgoniPerché l'illuminazione è essenziale per le conversioni di furgoni
Scegliere il miglior impianto di illuminazione per camper a 12 V
Perché l'illuminazione è essenziale per le conversioni di furgoni? Un numero sempre maggiore di persone abbraccia lo stile di vita nomade, viaggiando in camper, RV, furgoni o autobus riconvertiti. Se per alcuni vivere in un piccolo camper può sembrare difficile, altri passano anni a trasformare vecchi veicoli in case accoglienti o in rifugi per viaggi su strada. Un camper può essere...
Quale striscia LED-SMD-o-COB-è-superiore?Quale striscia LED-SMD-o-COB-è-superiore?
Qual è la striscia LED migliore, tra MSD e COB?
Dall'illuminazione di servizio a quella d'accento, l'illuminazione a strisce LED ha guadagnato popolarità per una serie di usi. Ma la scelta del tipo di striscia LED più adatto può essere impegnativa, soprattutto quando sono disponibili strisce LED SMD e COB. Vediamo le differenze tra le strisce LED SMD e COB in...
Tre problemi principali che preoccupano maggiormente gli utenti di strisce LEDTre problemi principali che preoccupano maggiormente gli utenti di strisce LED
Tre problemi principali che preoccupano maggiormente gli utenti delle strisce LED
Quali sono i principali problemi che gli utenti si preoccupano di più prima di acquistare strisce LED? SignliteLED è attiva nel settore delle strisce LED da 10 anni. Dopo aver contattato diverse tipologie di clienti, l'azienda ha concluso che i problemi più comuni tra i clienti che acquistano strisce LED includono principalmente i seguenti...

Condividere:

Facebook
Cinguettio
Pinterest
LinkedIn
Iscriviti
Notificami
ospite
0 Commenti
Il più vecchio
Più recente Più votato
Feedback in linea
Visualizza tutti i commenti

Cerca nel blog SignliteLED

Categorie

In cima

Richiedi un preventivo adesso