LED strips are widely used for decoration and lighting, but voltage drop issues often cause significant brightness reduction at the ends. This report, based on product test data developed by the engineering department, aims to evaluate voltage drop characteristics and provide guidance for production and installation.

Объективная цель

This test report, completed by the Engineering Department, conducts systematic testing on voltage drop for LED strips (including SMD and COB strips). The objective is to verify the magnitude of voltage drop in standard strips and, based on the test data, evaluate whether the strip design is reasonable and meets user requirements, thereby enabling further improvements.

Measurement Equipment and Environment

  • Digital Multimeter (FLUKE), 12V/24VDC Regulated Power Supply, Constant-Temperature Soldering Iron
  • Temperature: 28°C ±5°C
  • Humidity: 65% ±5%

Test Sample

A total of 12 pieces, including 6 pieces of Светодиодные ленты SMD and 6 pieces of Светодиодные ленты COB.

Светодиодная лента SMD
АртикулNumber of LEDsНапряжениеLength of the LED Stripпечатная плата Ширина
160 LEDs/m12V10m8 мм
2120 LEDs/m12V10m8 мм
3120 LEDs/m24V10m8 мм
4120 LEDs/m24V5 м5 мм
5120 LEDs/m24V Constant Current5 м10 мм
6240 LEDs/m24V10m10 мм
Светодиодная лента COB
АртикулNumber of LEDsНапряжениеLength of the LED Stripпечатная плата Ширина
1320 LEDs/m12V5 м8 мм
2320 LEDs/m24V5 м8 мм
3384 LEDs/m24V5 м8 мм
4480 LEDs/m12V10m8 мм
5528 LEDs/m12V5 м10 мм
6528 LEDs/m24V10m10 мм

Testing Method

1) Adjust the DC power supply to output the correct voltage according to the LED strip’s voltage specifications. Verify the voltage accuracy using a multimeter.

2) Test the voltage value at the end point of each meter of LED strip using a multimeter and record the data.

3) Test the current data for each meter of LED strip using a multimeter. Calculate the power per meter using the formula P=UI and record the data.

4) After completing voltage and current measurements for each meter, solder the next meter of LED strip using a soldering iron. Repeat steps 2 and 3 until testing reaches the end point.

5) Record and preserve all data.

SMD LED Strip Voltage Drop Test Data

Напряжение падение пробный Report для 60 светодиодов/м 12V LED Полоса
Длина1 метр2 метра3 метра4 метра5 м6m7m8m9m10mСила(Вт)печатная плата специальный
10m10.349.559.028.658.408.238.118.048.007.9815.24Width 8mm
copper
thickness:
18/25μm
9m10.559.699.128.738.478.298.188.128.10 15.12
8m10.569.709.138.768.518.358.268.24  15.00
7m10.559.719.168.808.588.468.41   14.88
6m10.549.739.218.898.728.67    14.40
5 м10.579.809.339.088.89     14.16
4 метра10.679.979.609.48      13.56
3 метра10.8110.2810.10       12.36
2 метра11.1410.84        9.79
1 метр11.64         5.77
Примечание: The middle value represents voltage, with units in volts (V).
Table 1

Voltage Drop Test Report for 120LEDs/m 12V LED Strip
Длина1 метр2 метра3 метра4 метра5 м6m7m8m9m10mСила(Вт)печатная плата Сpec
10m10.499.669.118.748.488.308.188.108.068.0424.00Width 8mm,
copper
thickness:
35/35μm
9m10.499.669.128.758.498.338.228.168.17 23.82
8m10.509.679.138.778.538.388.308.27  23.72
7m10.509.689.168.828.608.488.45   23.54
6m10.519.729.228.918.748.69    23.19
5 м10.549.789.339.089.01     22.72
4 метра10.629.939.579.46      21.86
3 метра10.7710.2310.07       20.04
2 метра11.0510.82        16.20
1 метр11.61         9.80
Примечание: The middle value represents voltage, with units in volts (V).
Table 2

Voltage Drop Test Report for 120LEDs/m 24V LED Strip
Длина1 метр2 метра3 метра4 метра5 м6m7m8m9m10mСила(Вт)PCB Spec
10m22.5621.5020.6720.0119.4919.1018.8018.6018.4918.4641.95Width 8mm,
copper
thickness:
35/35μm
9m22.5821.5620.7620.1419.6719.3119.0818.9418.89 41.00
8m22.6321.6420.8820.3119.8919.6119.4319.38  40.15
7m22.7021.7521.0620.5620.2120.0119.94   38.40
6m22.8021.9321.3220.9120.6720.59    36.38
5 м22.9122.1421.6621.3721.28     33.36
4 метра23.0622.4822.1322.02      29.47
3 метра23.2822.8922.77       24.00
2 метра23.5623.42        17.00
1 метр23.91         9.00
Примечание: The middle value represents voltage, with units in volts (V).
Table 3

Напряжение падение пробный Report для 120 светодиодов/м 24V LED Полоса
Длина1 метр2 метра3 метра4 метра5 м     Сила(Вт)печатная плата специальный
5 м23.3322.9222.6322.4722.42     21Width 5mm,
copper
thickness:
35/35μm
4 метра23.5223.2123.0322.97      17.70
3 метра23.6523.3923.34       13.90
2 метра23.7223.63        9.30
1 метр23.95         4.80
Примечание: The middle value represents voltage, with units in volts (V).
Table 4

Напряжение падение пробный Report для 120 светодиодов/м 24V непрерывный Текущий LED Полоса
Длина1 метр2 метра3 метра4 метра5 м     Сила(Вт)печатная плата специальный
5 м22.6521.9321.4221.1221.02     80.64Width 10mm
copper
thickness:
25/25μm
4 метра22.9222.4122.1122.00      63.12
3 метра23.2522.9422.83       47.52
2 метра23.5523.45        31.68
1 метр23.84         16.08
Примечание: The middle value represents voltage, with units in volts (V).
Table 5

Напряжение падение пробный Report для 240 светодиодов/м 24V LED Полоса
Длина1 метр2 метра3 метра4 метра5 м6m7m8m9m10mСила(Вт)печатная плата специальный
10m22.7621.1821.1720.6020.1419.7919.5219.3419.2319.2089.52Ширина 10 мм
copper
thickness:
25/25μm
9m22.8021.9521.2720.7420.3220.0019.8019.6819.64 86.80
8m22.8822.0821.4520.9720.6220.3720.2220.18  83.52
7m22.9622.2221.6521.2420.9520.7820.73   78.91
6m23.0522.4021.9221.5921.4021.34    72.96
5 м23.1822.6222.2422.5821.96     65.40
4 метра23.3322.9122.6622.58      55.92
3 метра23.5123.2323.15       44.44
2 метра23.7323.64        31.20
1 метр23.97         16.00
Примечание: The middle value represents voltage, with units in volts (V).
Table 6

Test Results Statistics Table

АртикулLEDs/mLength(m)Starting Voltage(V)Endpoint Voltage(V)Напряжение Drop
16010127.9833.5%
212010128.0433.0%
3120102418.4623.1%
412052422.426.6%
512052421.0212.4%
6240102419.220%

Summary Analysis

For the 60 LEDs/m and 120 LEDs/m light strips in Tables 1 and 2, the voltage drops to 7.98V and 8.04V, respectively, at a 10-meter length. The maximum voltage drop reaches 33.5%, indicating a significantly excessive voltage drop. Since both 60-LED and 120-LED strips consist of three LEDs in series (3V x 3 = 9V), ideally, the voltage drop should be maintained above 9V. Therefore, the voltage drop values for these two LED strips need improvement. This can be achieved by widening the circuit board or thickening the copper foil, or by controlling the LED forward voltage (VF) within a range below 2.8V.

Tables 3, 4, 5, and 6 all use a DC 24V power supply with 6 LEDs in series. We calculate the voltage required for the LEDs in series: 3V x 6 = 18V. Among all endpoint test values, Table 3 shows the lowest voltage drop at 18.46 V, exceeding the 18 V requirement and essentially meeting the voltage for 6 LEDs in series, thus qualifying as acceptable. Figure 5 employs constant-current mode, maintaining consistent power output of 16 W/m at both ends with negligible brightness decay, demonstrating excellent consistency.

Causes of High Voltage Drop:

This primarily results from excessive strip length and current, increasing PCB resistance and “consuming” voltage. Excessive voltage drop directly causes noticeable dimming at the strip’s end and may even lead to color distortion.

КБ LED Strip Voltage Drop Test Data

Напряжение падение пробный Report для 320 светодиодов/м 12V КБ LED Полоса
Длина1 метр2 метра3 метра4 метра5 м     Сила(Вт)печатная плата специальный
5 м11.4011.0710.8710.7710.73     25.20Width 8mm
copper
thickness:
25/25μm
4 метра11.4011.1010.9510.90      24.00
3 метра11.4511.2111.14       22.80
2 метра11.5611.45        19.20
1 метр11.81         12.00
Примечание: The middle value represents voltage, with units in volts (V).
Table 1

Напряжение падение пробный Report для 320 светодиодов/м 24V КБ LED Полоса
Длина1 метр2 метра3 метра4 метра5 м     Сила(Вт)печатная плата специальный
5 м23.5823.2623.0322.9022.86     33.60Width 8mm
copper
thickness:
25/25μm
4 метра23.6523.3823.2323.00      29.76
3 метра23.7523.5723.5123.18      24.40
2 метра23.8823.82        17.20
1 метр24.00        9.00
Примечание: The middle value represents voltage, with units in volts (V).
Table 2

Напряжение падение пробный Report для 384LEDs/m 24V КБ LED Полоса
Длина1 метр2 метра3 метра4 метра5 м     Сила(Вт)печатная плата специальный
5 м23.6723.4123.2323.1223.08     46.30Width 8mm,
copper
thickness:
25/50μm
4 метра23.7623.5623.4523.42      38.10
3 метра23.8523.7423.70       29.20
2 метра23.9523.91        19.80
1 метр24.00         10.10
Примечание: The middle value represents voltage, with units in volts (V).
Table 3

Напряжение падение пробный Report для 480 светодиодов/м 12V КБ LED Полоса
Длина1 метр2 метра3 метра4 метра5 м6m7m8m9m10mСила(Вт)печатная плата специальный
10m11.3310.9710.7310.5710.4610.3810.3310.2910.2710.2624.70Width 8mm
copper
thickness:
25/25μm
9m11.3310.9810.7410.5810.4710.4010.3510.3210.31 24.60
8m11.3310.9810.7510.5910.4910.4310.3910.38  24.40
7m11.3310.9810.7610.6210.5210.4710.45   24.20
6m11.3411.0010.7810.6610.5810.56    24.00
5 м11.3511.0211.8310.7310.70     23.50
4 метра11.3811.0810.9310.88      22.60
3 метра11.4411.2011.13       21.00
2 метра11.5611.45        17.40
1 метр11.80         10.60
Примечание: The middle value represents voltage, with units in volts (V).
Table 4

Напряжение падение пробный Report для 528 светодиодов/м 12V КБ LED Полоса
Длина1 метр2 метра3 метра4 метра5 м     Сила(Вт)печатная плата специальный
5 м11.4311.1110.90 10.7910.76     34.44Width 10mm
copper
thickness:
25/25μm
4 метра11.4511.1711.01 10.96      32.88
3 метра11.5211.3111.23       29.52
2 метра11.6311.53        23.40
1 метр11.89         14.40
Примечание: The middle value represents voltage, with units in volts (V).
Table 5

Напряжение падение пробный Report для 528 светодиодов/м 24V КБ LED Полоса
Длина1 метр2 метра3 метра4 метра5 м6m7m8m9m10mСила(Вт)печатная плата специальный
10m23.3722.9322.5722.2922.0721.8921.7721.6921.6421.6270.80Width 10mm
copper
thickness:
25/25μm
9m23.3822.9522.6122.3422.6021.9721.8722.0421.80 69.36
8m23.4022.9822.6622.4122.2322.1122.0322.01  67.20
7m23.4223.0322.7322.5222.3622.2822.24   64.80
6m23.4823.1322.8522.6722.5722.53    61.20
5 м23.5223.2223.0022.8822.83     55.92
4 метра23.6123.3623.2123.16      48.96
3 метра23.7023.5323.47       39.84
2 метра23.8223.76        28.32
1 метр23.94         15.20
Примечание: The middle value represents voltage, with units in volts (V).
Table 6

Test Results Statistics Table

АртикулLEDs/mLength(m)Starting Voltage(V)Endpoint Voltage(V)Напряжение Drop
132051210.7310.6%
232052422.864.7%
338452423.083.8%
4480101210.264.5%
552851210.7610.3%
6528102421.629.9%

Заключение

Under 12V power supply, the voltage drops in Figures 1 and 5 are both around 10%, indicating slightly higher values. Figure 4 exhibits an excellent performance with a lower voltage drop of 4.5%.

Under 24V power supply, Figures 2 and 3 exhibit voltage drops of 4.7% and 3.8%, respectively, demonstrating excellent performance. Figure 6 shows a drop of 9.9%, which is slightly higher. Figure 3 achieves the lowest drop due to its PCB substrate copper foil thickness of 50 μm—twice as thick as the 25 μm thickness of others—which is the primary reason for its minimal voltage drop.

Among the COB LED strip voltage drop test results, the largest drop was 10.6% in Figure 1, while the smallest was 3.8% in Figure 3. Their voltage drop ranges fall within acceptable limits, and all six COB LED strips meet product testing requirements.

Appendix: LED Industry Voltage Drop Standards

Industry standards for LED strip voltage drop typically reference international specifications like IEC 62717, with core requirements including:

  • Voltage Stability: Current variation ≤ ±5% when rated voltage fluctuates by ±10%
  • Voltage Drop Limit: No specific percentage specified, but supply voltage must remain stable within ±0.2%
  • ‌Test Conditions: Conducted at 25°C ±1°C with relative humidity ≤65%

In practical applications, voltage drop for 12V systems is recommended to be controlled within 10%, while 24V systems should maintain it below 5%. Testing requires a constant current source to ensure LEDs operate at specified current values.

Сравнительная проверка изменений цветовой температуры в светодиодной ленте с покрытием и поливомСравнительная проверка изменений цветовой температуры в светодиодной ленте с покрытием и поливом
Сравнительная проверка изменений цветовой температуры в светодиодной ленте с покрытием и поливом
Цели теста на старение и экспериментальное описание среды ОПРЕДЕЛЕНИЕ ИЗГОТОВЛЕНИЕ СТАНОВИТЕЛЬНОЙ ТЕСТИРОВАНИЕ: Оценить сдвиг цветовых температур в светодиодах после нанесения капельной смолы на обычно используемые водонепроницаемые светодиодные полосы при различных цветовой температуре. Записывайте данные тестирования и сравнивайте колебания цветовой температуры до и после применения процессов гидроизоляции (капельное покрытие против горшечной смолы) до...
DALI VS PWM: выбор правильного протокола затемнения для вашей системы интеллектуального освещения
Современные системы интеллектуального освещения делают не только включение и выключение света, но и создают адаптируемую среду, повышающую комфорт, эффективность и стиль. За каждым плавным изменением яркости скрывается протокол затемнения, который тихо формирует пользовательский опыт. Среди наиболее широко используемых в коммерческих проектах - DALI и PWM,...
A-Guide-to-LED-Lighting-for-Wood-Panel-WallsA-Guide-to-LED-Lighting-for-Wood-Panel-Walls
Руководство по светодиодному освещению для стен из деревянных панелей
Акустические деревянные панели для стен были одним из самых популярных продуктов в мире в последние годы, и теперь появляется все больше способов сделать их декор с помощью различных светодиодных аксессуаров. Например, светодиодные ленты WoodUpp - это один из идеальных способов дополнить...
Преимущества использования светодиодных лент для зеркалПреимущества использования светодиодных лент для зеркал
Руководство по зеркальной светодиодной ленте
Светодиодное освещение - распространенный выбор в современном домашнем декоре благодаря своей энергоэффективности, гибкости и эстетичности. И одним из самых интересных применений светодиодной технологии является интеграция светодиодных лент в зеркала. Светодиодные ленты для зеркал - отличное решение для повышения функциональности и...
Светодиодная лента WS2812B VS светодиодная лента SK6812Светодиодная лента WS2812B VS светодиодная лента SK6812
Светодиодная лента WS2812B VS светодиодная лента SK6812: Что лучше?
Что такое WS2812B светодиодная лента? Светодиодная лента WS2812 - это 3-канальная адресная лента со встроенной ИС, управляемая специальными светодиодными контроллерами. Один светодиод как один индивидуально адресуемый пиксель, ИС интегрирована в светодиод, не видна на ленте. Меньше компонентов на ленте, легче для установки, и Бен. Эти светодиоды очень...
Do-neon-lights-pose-a-fire-riskDo-neon-lights-pose-a-fire-risk
Представляют ли неоновые лампы пожарную опасность?
Распространенным вариантом освещения, обеспечивающим яркий и поразительный внешний вид, являются неоновые лампы. Они часто используются в декоративном освещении, вывесках и рекламе. Некоторые люди беспокоятся о том, что неоновые лампы могут стать причиной пожара. Ответ на этот вопрос мы рассмотрим в этой статье блога. The...

Делиться:

Фейсбук
Твиттер
Пинтерест
LinkedIn
Подписаться
Уведомить о
Гость
0 Комментарии
Старые
Новые Популярные
Межтекстовые Отзывы
Посмотреть все комментарии

Поиск в блоге SignliteLED

Категории

Наверх

Получите расценки сейчас