It’s quite common that LED strips stops working after being cut, especially for those people who dose not have much experience on DIY. On the condition that the strips do work before cutting, here are the potential causes and solutions.

Parts of LED strip is not working

1. Incorrect cutting point

Cause: Flexible LED strips is cuttable, usually the cutting points is marked by a line or a scissor icon. Cutting the strip at any point other than the designed points can break the circuit, which causes this unit of the strip not working.

Solution: Cut off this damaged unit at correct cutting point, expand another unit on strip by soldering or solderless connectors if needed.

Incorrect cutting point

2. Electrostatic damage

Cause: Static electricity creates high-voltage spike which easily breakdown LED chip’s P-N junction, it happens by touching soldering pad or LED chips directly.

Solution: Put on anti-static wrist strap before cutting, other static elimination works as well.

Electrostatic damage

3. Connection issue

Cause: When connect two strips together after cutting, faulty soldering or bad connection by ตัวเชื่อมต่อแบบไม่มีบัดกรี leads to the following strips not working.

Solution: Inspect the solder joints, re-solder the weak joints; Replace connectors, ensure it fits well and tight.

Connection issue

Entire LED strip is not working

1. Short circuit

Cause: Forget to turn off the power while cutting the strips or solder positive and negative polarity together accidentally, this short circuit creates surge current which burns LED chips;

Solution: Disconnect strips to LED driver before cutting; Check if there is any soldered joints problem.

Short circuit

2. Polarity Reversal

Cause: a. Reversing the polarity when connect strips to LED驱动器.

   b. Reversing the polarity when solder cable or use solderless connectors. Such as “+” and “-” mixed or “R”, “G”, ”B” and “+” mixed.

Solution: Double check polarity of cable and soldering joints before power on.

Polarity reversal to power supply
Reversed polarity of cable soldering 2

3. Connection issue

Cause: Cable is not soldered to strips well or connectors does not fit strips well may cause incomplete electric circuit

Solution: Make sure the connectors or soldered joints are properly aligned and securely attached to the copper pads. If using snap or solderless connectors, ensure they are compatible with the strip’s width and pin configuration.

4. Power supply issue

Cause: After cutting and reconnecting LED strips, the power supply might not provide adequate voltage or current, especially if the strip length has changed significantly.

Solution: Calculate how much power the new strip need, change power supply if the old one is not powerful enough.

Additional tips:

1. Disconnect power supply before cutting and reconnecting.

2. Check all the solder joints and other connections before power on.

3. Prepare some equipment, anti-static wrist strap for static elimination, multimeter for measuring voltage and current, checking if the solder joints is shorted.

4. Contact us for help.

Advertising Light Box LED Rigid Strip Selection GuideAdvertising Light Box LED Rigid Strip Selection Guide
Advertising Light Box LED Rigid Strip Selection Guide
In advertising light boxes, the choice of LED light source directly affects the display effect, especially in airports, subways, shopping malls, retail chains, and other scenarios. The lightbox not only conveys information but also carries the brand image. Compared with traditional light sources, LED rigid strips have become the first...
About Dimmable COB LED Strip LightsAbout Dimmable COB LED Strip Lights
About Dimmable COB LED Strip Lights
In modern lighting technology, LED strips are favored for their flexibility, energy efficiency, and variety of applications. Dimmable LED strip lights have revolutionized modern lighting solutions. Whether you're looking to improve the ambiance of your home or design a professional workspace, understanding how dimmable LED strips work is essential to...
What is a waterproof IP rating-01What is a waterproof IP rating-01
คู่มือไฟ LED Strip กันน้ำระดับ IP
选择LED灯带时,理解防水IP等级至关重要。该等级决定产品对固体和液体的防护能力,直接影响其在不同环境中的适用性。选购时需考虑...
ไฟ LED-แสงสี-อุณหภูมิ-เปรียบเทียบ-5000K-Vs.-6000Kไฟ LED-แสงสี-อุณหภูมิ-เปรียบเทียบ-5000K-Vs.-6000K
การเปรียบเทียบอุณหภูมิสีของแสง LED: 5000K เทียบกับ 6000K
อุณหภูมิสีเป็นพารามิเตอร์ที่อธิบายสีของแหล่งกำเนิดแสงที่มองเห็นได้และวัดเป็นเคลวิน (K) ค่าเฉพาะที่เรากำลังพูดถึง เช่น 5000K หรือ 6000K เป็นอุณหภูมิสีที่สัมพันธ์กัน (CCT) อุณหภูมิสีที่สัมพันธ์กัน (CCT) ใช้เพื่ออธิบายสีของ...
led-aluminum-profile-applications_240816led-aluminum-profile-applications_240816
วิธีการใช้โปรไฟล์อลูมิเนียมสำหรับแสงทางอ้อม?
แสงทางอ้อมเหมาะสำหรับโครงการออกแบบสถาปัตยกรรมและตกแต่งภายใน อุปกรณ์ติดตั้งเหล่านี้มีเป้าหมายเพื่อให้แสงสว่างแก่พื้นที่ โดยไม่แสดงแหล่งกำเนิดแสง แสงสะท้อนจากผนังและเพดานโดยตรงทำให้เกิดแสงที่นุ่มนวลและกระจายตัวซึ่งช่วยเพิ่มบรรยากาศของห้อง มันปรับปรุง...
Examining-3000K-vs-4000K-LED-Lighting-Options-for-Interior-DesignExamining-3000K-vs-4000K-LED-Lighting-Options-for-Interior-Design
Examining 3000K vs 4000K LED Lighting Options for Interior Design
Selecting between the 3000K and 4000K alternatives for LED lighting for your house might be challenging. When choosing the best lights for your needs, it's critical to understand how they differ despite the fact that both offer excellent illumination and energy savings. We examine the advantages of every kind of...

แบ่งปัน:

เฟสบุ๊ค
ทวิตเตอร์
พินเทอเรสต์
ลิงค์อิน
สมัครสมาชิก
แจ้งเตือนเรื่อง
访客
0 ความคิดเห็น
เก่าแก่ที่สุด
ใหม่ล่าสุด ได้รับการโหวตมากที่สุด
การตอบรับแบบอินไลน์
ดูความคิดเห็นทั้งหมด

ค้นหาบล็อก SignliteLED

หมวดหมู่

รับใบเสนอราคาทันที